Vibration absorber
Z-2000NW
Flange type for general use
- Pump
- Water tank/cooling tower
- Cold and hot water generator (cold and hot water)
- Cold and hot water generator (cooling water)
- Air conditioning piping
- Water supply piping
- Hot water piping
- Utility water piping
- Oil piping
- Steam piping
- Air piping
- Please refer to “Product Drawings” and “Product Specifications” for detailed information such as materials of each part.
- Please refer to the “Installation Instructions” for installation procedures.
Applications and Features
Purpose
- Absorbing pump vibration, adjusting misalignment of piping work, piping component for seismic facility.
Specification
- -20~300℃
- 1.0MPa
- The maximum working pressure is based on the bellows material SUS304, normal temperature, single blade.
- JIS5K、JIS10K
Features
- Special bellows are used to disperse stress accumulation. Furthermore, the non-welded construction of the bellows provides excellent durability in areas subject to vibration and impact pressure.
- Stainless steel wetted parts, both loose flange type.
- Stainless steel flange material is also available. (Standard material is SS400)
- Changes in material, specifications, etc. are available upon request.
Note
- Please use general commercially available gaskets for joint sheet type gaskets. (Thickness: 3.0 mm)
- PTFE wrapped gaskets cannot be used.
- Use expanded graphite-based joint sheets for steam piping. (Thickness: 3.0 mm)
- For spiral gaskets, please contact us.